V-Twin System

Zatni standard testiranja sa EMIT tehnologijom

The V-Twin® System maksimizuje performanse Syva® EMIT® reagensa. Brz, jednostavan za upotrebu, obrađuje više testova po nižim cenama, uključuje sopstveni bekap sistem za veću pouzdanost. Veliki izbor testova na koncentraciju i zloupotrebu lekova, terapeutske doze lekova, i imunosupresiva. Testiranje nije nikada bilo pouzdanije.
Syva® EMIT® DAT Assays
Amphetamines
6-Acetylmorphine
Barbiturate
Benzodiazepine
Cocaine Metabolite
Cannabinoid
Ecstasy
Ethyl Alcohol
LSD
Methadone
Methaqualone
Opiate
Phencyclidine
Propoxyphene

Distributed Assays
Buprenorphine*
Ethyl glucuronide (EtG)*
Meperidine*
Methadone metabolite (EDDP)*
Oxycodone*
Tramadol*

Syva® EMIT® Serum Tox™ Assays
Acetaminophen
Barbiturate
Benzodiazepine
Salicylic Acid
Tricyclic Antidepressants

Syva® Validity SVT Assays
Creatinine
Nitrites
Oxidants
pH
Specific Gravity

Syva® EMIT® TDM Assays
Amikacin
Caffeine
Carbamazepine
Digoxin
Disopyramide
Ethosuximide
Gentamicin
Lidocaine
Methotrexate
NAPA
Phenobarbital
Phenytoin
Primidone
Procainamide
Quinidine
Theophylline
Tobramycin
Valproic Acid
Vancomycin

Syva® EMIT® 2000 ISD Assays
Cyclosporine A
Cyclosporine A Extended Range
Mycophenolic Acid (MPA)
Sirolimus
Tacrolimus

Throughput
Up to 260 EMIT® tests per hour with two reagents
Up to 130 EMIT® tests per hour with three reagents
Reagent system
2 Emit reagent rotors
Each rotor has 14 positions for 30 mL bottles and 12 positions for 15 mL bottles, all positions can be assigned as R1, R2 and R3; adapters for 3, 6 and 15 mL bottles
Reagent rotor compartment is cooled to approximately 12°C
Reagent Volumes:
Reagent 1 volume 110-400 μL
Reagent 2 volume 0-180 μL
Reagent 3 volume 0-180 μL
Preheated reagent probes with level detection and integrated mixer
Sample system-providing continuous loading
Positive sample identification
Sample rotor containing:
80 barcode read samples positions
20 calibrators
10 controls
STAT and pediatric functionality
Continuous loading
Internal barcode reading
Primary tubes (13 or 16 mm OD)
All positions can contain 5 mL or 10 mL primary tubes or sample cups
Sample volume 1-30 μL per test, programmable in steps of 0.1 μL
Sample probe with level detection and integrated mixer
Sample predilution (Dual Reagent Mode only) Programmable ratios 1:5, 1:10, 1:20, 1:30, 1:40, 1:50 with 3 possible diluents
Pipetting system (2)
HAMILTON syringes and valve block
Reagent syringe 1000 μL
Sample syringe 100 μL
Cuvette rotor (2)
Semi-disposable rotor with 48 cuvettes, path length 7 mm
Minimum measuring volume 220 μL
Measuring temperature 37°C, controlled by Peltier elements
Washing units (2)
Cuvette-washing with 4 x 500 μL of water. The unit is equipped with liquid sensors. Waste is separated into diluted and concentrated (sample/reagent mixture and optional ISE-unit) waste. Cuvettes are dried before use.
Deionized water: 1L per hour while in use.
Light source Quartz-iodine lamp 12 V-20 W
Wavelength range
2 optical units each with a 8-position filter wheel
Automatic wavelength selection by 8-position filter wheel (340, 415, 505, 546, 570, 660, 700 and 600 nM), half bandwidth 8 to 12 nM
Photometric range -0.1 to 3.0 Absorbance
Analytical modes
Kinetic measurement with linearity check
Bichromatic endpoint measurement with or without bichromatic reagent blank and/or sample blank correction
Two point measurement
Automatic rerun with sample reduction
Ambient temperature
15-32°C
Maximum humidity 80 %
Calculation modes
Logit Log4
Nonlinear calibration curves
Graphic plot of all measuring points
Prozone check for immunology tests
Cut-off declaration
Quality control
Up to 15 different controls can be defined, 3 per test
Westgard rules
Levey-Jennings plots
Computer
Windows® based
PENTIUM processor
Monitor 1024 x 768 pixels
CD-ROM drive
Ports: 2 serial, 1 USB and 1 printer port
Printer
The application supports two printers simultaneously; one for patient reports and one for calibration and system data
Most printers supported by Windows® can be connected.
Barcode reader (option) Handheld CCD barcode reader (can read all common barcodes) used for test requisition and reagent identification
Languages
English
French
German
Italian
Spanish
Others on request
Electrical 120 V AC ± 10%, 20A @ 60 Hz, 1.5 kV A
Dimensions (floor) 46 x 45 x 30 in. (117 x 115 x 77 cm) (W x H excluding monitor x D)
Weight 418 lbs. (190 kg)